I N S T A L L A T I O N I N S T R U C T I O N S
IN-WALL ENCLOSURE
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
PAC502
Installation Instructions
PAC502
DIMENSIONS
.39
9.9
4X 1.75
44.5
3.63
92.1
12X .136
3.5
20X 5/16"-18 THREADS
4X .77
19.4
4X 1.63
41.3
G ROUNDING
SC REWS
2X 12.00
304.8
20.00
508
6X 3.94
100
NOTES:
3.85
97.9
30.00
762
2X 2.99
76
2X 2.20
55.9
DIMENSIONS:
INCHES
[MILLIMETERS]
.14
3.5
1.75
44.5
1" AND 2" TRADE SIZE
PIPE C ONDUIT
LEGEND
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Potloodmerkteken
Marquage au crayon
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Hex-Head Wrench
Destornillador Phillips
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Zeskantsleutel
Clé à tête hexagonale
3
PAC502
Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
3/16"
PARTS
Grounding screw and washer
installed at factory
Earthing symbol IEC 60417 No. 5019
affixed adjacent to grounding terminal.
B (4)
[Mounting
spacers]
A (1)
[PAC502]
E (6)
08 x 1/2"
C (8)
M7 x 40mm
[Extras if needed for
installing electrical box]
D (4)
M7 x 50mm
F (1)
M4
[Allen driver bit]
K (16)
J (12)
[Tape squares]
[5-1/2" cable tie]
L (4)
[9/16"]
H (4)
[Cable tie mounts]
G (4 - 2 long, 2 short)
[Trim pieces]
4
Installation Instructions
PAC502
Frame Housing
INSTALLATION
The exposed portion of the center wood stud must be removed
and the resulting cavity completely framed with wood. The
following steps are suggested. The actual procedure is
dependent upon the specific installation.
WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEATH OR SERIOUS PERSONAL INJURY! This accessory
should be installed by qualified personnel.
Site Preparation
Locate and Prepare Mounting Site
1. Identify a suitable wall location for the in-wall enclosure.
WARNING: STRUCTURAL FAILURE HAZARD! FAILURE
TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO
DEATH OR SERIOUS INJURY! Ensure removal of center
stud will not cause unacceptable loss of structural strength.
Consult a qualified building contractor and applicable building
codes.
IMPORTANT ! : The PAC502 is designed for in-wall
installation spanning a minimum of three wood studs, 16"
on center. Installation of PAC502 in 2 x 4 wall results in
nearly direct contact with vertical studs and back wall.
Inadequate space will remain for electrical wires/cables,
plumbing, ductwork, or insulation. Locate installation
accordingly.
1. Remove exposed portion of center wood stud flush with
upper and lower drywall edges.
Support
Blocks
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.
Horizontal Framing
Top View
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.
Wood
Screws
(5 places)
(Typical for each
support block)
2. Using a stud sensor, locate and mark studs.
3. Center and level housing between marked studs.
Figure 2
4. Using PAC502 (A) as a template, draw pencil line
completely around in-wall enclosure. (See Figure 1)
2. Cut four 8" long support blocks out of 2" x 4" wood.
5. Cut drywall on outside edge of line and remove.
3. Using three #10 x 2-1/2" countersunk wood screws (not
provided), attach each support block to the studs (See
Figure 2)
Wood Studs
NOTE: Ensure screws are far enough from block end to
prevent interference with framing screws installed in In-
Wall Enclosure Installation section.
4. If necessary, cut rectangular hole in horizontal framing to
accommodate the PAC-GB1 Listed electrical box accessory
(not included).
5. Attach horizontal framing to each support block with two
#10 x 2-1/2" countersunk wood screws (not provided).
(See Figure 2)
In-Wall Enclosure Installation
1. Install PAC-GB1 Listed electrical box accessory (not
included) into the PAC502 (A) following instructions
included with the PAC-GB1.
2. Connect electrical wiring according to National Electrical
Code(NEC) ANSI/NFPA 70 - 2008, wire connection
requirements.
(A)
3. Route audio/visual cables into housing.
Figure 1
5
PAC502
Installation Instructions
4. Center PAC502 (A) in opening and insert into opening. Align
front of box with front face of wall. (See Figure 3)
NOTE: The PAC502 has 1/2" total clearance between the two
studs. The spacers allow side to side adjustment.
7. Drill eight 3/16" diameter pilot holes in horizontal framing at
top and bottom mounting holes. (See Figure 5)
(A)
8. Attach the PAC502 (A) to horizontal framing using eight
M7 x 40mm Allen head connector screws (C) using an M4
Allen head drill bit (F). (See Figure 5)
7
x 8
Figure 3
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR
CABLES CAN CAUSE DEATH OR SERIOUS
PERSONAL INJURY! ALWAYS make certain area behind
mounting surfaces is free of electrical wires and cables
before cutting, drilling, or installing fasteners.
8
(C) x 8
Figure 5
DANGER: IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be
installed by qualified personnel using a UL Recognized No.
12AWG Green and Yellow grounding wire connected to
grounding lug on mount.
5. Drill four 3/16" diameter pilot holes in studs at side mounting
holes. (See Figure 4)
6. Attach the PAC502 (A) to side studs using four M7 x 50mm
Allen head connector screws (D) and mounting spacers (B)
using an M4 Allen head drill bit (F). (See Figure 4)
Grounding Lug Locations
(D) x 4
6
(B) x 4
x
x 4
5
Figure 4
Figure 6
6
Installation Instructions
PAC502
Trim Kit (Optional)
1. Remove paper covering adhesive and affix three tape
squares (K) to inside lower flange of each trim piece (G).
(See Figure 7)
2. Orient trim pieces (G). (See Figure 7)
3. Remove paper covering adhesive back from tape squares
(K) on trim and press trim (G) against inner wall of box.
(See Figure 7)
(G) x 4
3
(K) x 16
1
Figure 7
Installing Mount Assembly
1. Install mount assembly following instructions included with
the mount.
2. OPTIONAL: Cover unused mounting holes in PAC502 with
9/16" caps (L).
Cable Management
1. Attach all cables to display.
2. If necessary, use cable tie mounts (H) and cable ties (J) to
secure cables within PAC502.
7
PAC502
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
Chief Manufacturing, a products division
of Milestone AV Technologies
+31 (0)40 2668615
Asia Pacific
A
Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
8807-002019 Rev02
¤2010 Milestone AV Technologies,
a Duchossois Group Company
11/10
Fotan, Shatin, Hong Kong
852 2145 4099
852 2145 4477
P
F
|